Isolation Transformer


New Gold, Isolation & Ultra Transformer, Control Transformer, Auto Transformer (Single Phase, Two Phase & Three Phases). This Transformer can also be developed into step up & step down. The voltage range is 10 V to 5000 volt, & frequency 25 Hz to 500 Hz (General use 50 Hz & 60 Hz).
These Isolation Transformers reduce the effects of power line problems like Noise, Spikes, Surges Transients and neutral to a minimum.

CARE DISCRIPTION OF MACHINE & INSTRUMENT: -

Switching of electrical utilities in industrial & commercial environment generates spikes up to 6000 Volt & high frequency power line noises.
 
The spikes can cause the failure of thrusters, micro-processors, or other active electronic device.
 
The high frequency noises can interfere with Digital-Electronic equipment causing data corruption, erratic behavior, loss of memory etc.
 
The noise cut-off transformer eliminates such noises & attenuates the spikes to negligible values, providing complete protection against such electrical disturbances.
 
APPLICATION:-

·         Protect the CNC Machines, computer and Telecommunications equipment from damage due to electrical noise, spikes etc.
·         Where ground potential of system units are different from each other and are exposed to the effects of instability at high frequencies.
·         Where ground of the equipment cannot be earthed.
·         When no slightest current leakage is permitted in the equipment. Especially for computers and CNC controls less then 100 micro Amps is only permitted.
·         To protect against strong lighting, impulse noise, bus short- circuit, accidental discharge of capacitors etc. When no slightest current leakage is permitted in the equipment.
·         To shield large number of electronic equipment which individually also are producing different type of electrical noise at a common busbar typically CNC machines, Drives, hardening equipment etc.


  • 1 kva 3 phase isolation transformer with wago conector


  • 2 KVA 3PHASE ISOLATION TRANSFORMER


  • 7.5 KVA 3 PHASE ISOLATION TRANSFORMER


  • 10 KVA 3 PHASE ISOLATION TRANSFORMER


  • 50 KVA 3 PHASE ISOLATION TRANSFORMER


  • 50 KVA 3 PHASE DSC00938 ISOLATION TRANSFORMER


  • HT TRANSFORMER UIT TYPE


  • SIDE VIEW OF ISOLATION TRANSFORMER


  • ULTRA ISOLATION TRANSFORMER



TECHNICAL SPECIFICATION: -

·    System Connections                                                                  Delta/ Star, Star/Delta , Star/Star (and in Single
      Voltage design as per customer require voltage                        phase Series & panel connection)
      10 volt to 5000 volt in single phase & three phase
      Design for frequency 25 Hz to 500Hz
      (General use 47 Hz to 60 Hz)
·    Ratios                                                                                         1:1 and 2:1(or as per customer requirement)
·    Regulation                                                                                  Better than 3.5 %
·    Di-electric strength                                                                    2500 V AC for 120 Sec
·    Insulation Resistance                                                                 More than 1000 Mega Ohms.
·    Coupling Capacitance                                                                0.1 PF for 100 db
·    Leakage Current                                                                        Less than 20 mocro Amps.
·    Common Model attenuation                                                      100 db
·    Construction Standards                                                             As per is 2026 part 1 &11.